Kruger Ecowatt K320 Series Operation Manual page 215

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Function
Name
code
Power display
calibration
P12.28
coefficient of
motor 2
Parameter display
P12.29
selection of motor
System inertia of
P12.30
motor 2
P12.31–
Reserved
P12.32
P13 group––SM control
Function
Name
code
SM injection
P13.00
current drop rate
When M=116%, protection is performed
after motor overload lasts for 1 hour;
when M=200%, protection is performed
after
motor
seconds; and when M≥400%, protection
is performed immediately.
1h
1m
Setting range: 20.0% –120.0%
0.00–3.00
0: Display by motor type. In this mode,
only parameters related to the present
motor type are displayed.
2
1: Display all. In this mode, all the motor
parameters are displayed.
0–30.000kgm2
Used to set the reduction rate of the
injection reactive current. When the active
current of the SM increases to some
extent, the injection reactive current can
be reduced to improve the power factor of
the motor.
Setting range: 0.0%–100.0% (of the motor
rated current)
Description
overload
lasts
Time t
Motor overload multiple
116 %
200 %
Description
-206-
Function parameter list
Default
for
60
1.00
0
0.000
Default Modify
80.0%
Modify