Ecowatt
Drive K320 series
®
Function
Name
code
P26.48–
Reserved
P26.52
P28 group––Master/slave control
Function
Name
code
Master/slave
P28.00
mode
Master/slave
P28.01
communication
data selection
Master/slave
P28.02
control mode
P28.03
Slave speed gain 0.0–500.0%
P28.04
Slave torque gain 0.0–500.0%
Description
Description
0: Master/slave control is invalid
1: The local machine is a master
2: The local machine is a slave
0: CAN
1: Reserved
Ones place: Master/slave running mode
selection
0: Master/slave mode 0
(The master and slave adopt speed control
and maintain the power balance by droop
control)
1: Master/slave mode 1
(The master and slave must be in the
same type of vector control mode. The
master is speed control, and the slave will
be forced to be in the torque control mode.
2: Master/slave mode 2
Start in the slave first speed mode
(master/slave mode 0) and then switch to
torque mode at a certain frequency point
(master/slave mode 1)
Tens place: Slave start command source
selection
0: Follow the master to start
1: Determined by P00.01
Hundreds
transmitting/master receiving data enable
0: Enable
1: Disable
-246-
place:
Slave
Function parameter list
Default Modify
Default Modify
0
0
0x001
100.0%
100.0%