Ecowatt
Drive K320 series
®
Function
Name
code
P05.31
AI2 middle value 1
Corresponding
P05.32
setting of AI2
middle value 1
P05.33 AI2 middle value 2
Corresponding
P05.34
setting of AI2
middle value 2
P05.35
AI2 upper limit
Corresponding
P05.36
setting of AI2
upper limit
AI2 input filter
P05.37
time
HDIA high-speed
P05.38
pulse input
function selection
HDIA lower limit
P05.39
frequency
Description
100%
-10V
AI2
Input filter time: to adjust the sensitivity of
analog
input.
Increasing
properly
can
enhance
anti-interference but may reduce the
sensitivity of analog input.
Note: AI1 supports the 0–10V/0–20mA
input. When AI1 selects the 0–20mA input,
the corresponding voltage of 20mA is 10V.
AI2 supports the -10–+10V input.
Setting range of P05.24: 0.00V–P05.26
Setting range of P05.25: -300.0%–300.0%
Setting range of P05.26: P05.24–10.00V
Setting range of P05.27: -300.0%–300.0%
Setting range of P05.28: 0.000s–10.000s
Setting range of P05.29: -10.00V–P05.31
Setting range of P05.30: -300.0%–300.0%
Setting range of P05.31: P05.29–P05.33
Setting range of P05.32: -300.0%–300.0%
Setting range of P05.33: P05.31–P05.35
Setting range of P05.34: -300.0%–300.0%
Setting range of P05.35: P05.33–10.00V
Setting range of P05.36: -300.0%–300.0%
Setting range of P05.37: 0.000s–10.000s
0: Input set through frequency
1: Reserved
2: Input set through encoder, used together
with HDIB
0.000 kHz – P05.41
-168-
Corresponding setting
AI
0
10V
20mA
AI1
-100%
the
value
analog
input
Function parameter list
Default Modify
0.00V
0.0%
0.00V
0.0%
10.00V
100.0%
0.030s
0
0.000
kHz