Ecowatt
Drive K320 series
®

6.1 What this chapter contains

This chapter lists all the function codes and corresponding description of each function code.

6.2 Function parameter list

The function parameters of the VFD are divided into groups by function. Among the function
parameter groups, the P98 group is the analog input and output calibration group, while the
P99 group contains the factory function parameters, which are user inaccessible. Each group
includes several function codes (each function code identifies a function parameter). A
three-level menu style is applied to function codes. For example, "P08.08" indicates the 8th
function code in the P08 group.
The function group numbers correspond to the level-1 menus, the function codes correspond
to the level-2 menus, and the function parameters correspond to the level-3 menus.
1.
The content of the function code table is as follows:
Column 1 "Function code ": Code of the function group and parameter
Column 2 "Name": Full name of the function parameter
Column 3 "Description": Detailed description of the function parameter
Column 4 "Default": Initial value set in factory
Column 5 "Modify": Whether the function parameter can be modified, and conditions for the
modification
"○" indicates that the value of the parameter can be modified when the VFD is in stopped
or running state.
"◎" indicates that the value of the parameter cannot be modified when the VFD is in
running state.
"●" indicates that the value of the parameter is detected and recorded, and cannot be
modified.
(The VFD automatically checks and constrains the modification of parameters, which helps
prevent incorrect modifications.)
2.
The parameters adopt the decimal system (DEC). If the hexadecimal system is adopted,
all bits are mutually independent on data during parameter editing, and the setting ranges at
some bits can be hexadecimal (0–F).
3.
"Default" indicates the factory setting of the function parameter. If the value of the
parameter is detected or recorded, the value cannot be restored to the factory setting.
4.
To better protect parameters, the VFD provides the password protection function. After a
password is set (that is, P07.00 is set to a non-zero value), "0.0.0.0.0" is displayed when you
6 Function parameter list
-132-
Function parameter list