Kruger Ecowatt K320 Series Operation Manual page 170

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Function
Name
code
Current setting in
P04.41
IF mode for AM 1
Proportional
coefficient in IF
P04.42
mode for AM 1
Integral coefficient
in IF mode for AM
P04.43
Frequency
threshold for
P04.44
switching off IF
mode for AM 1
Enabling IF mode
P04.45
for AM 2
Current setting in
P04.46
IF mode for AM 2
Proportional
coefficient in IF
P04.47
mode for AM 2
Integral coefficient
P04.48
in IF mode for AM
Frequency
threshold for
P04.49
switching off IF
mode for AM 2
When IF control is adopted for AM 1, the
function code is used to set the output
current. The value is a percentage in
relative to the rated current of the motor.
Setting range: 0.0–200.0%
When IF control is adopted for AM 1, the
function
proportional coefficient of the output
current closed-loop control.
Setting range: 0–5000
When IF control is adopted for AM 1, the
function code is used to set the integral
coefficient
1
closed-loop control.
Setting range: 0–5000
0.00– P04.50
0: Disable
1: Enable
When IF control is adopted for AM 2, the
function code is used to set the output
current. The value is a percentage in
relative to the rated current of the motor.
Setting range: 0.0–200.0%
When IF control is adopted for AM 2, the
function
proportional coefficient of output current
closed-loop control.
Setting range: 0–5000
When IF control is adopted for AM 2, the
function code is used to set the integral
coefficient of output current closed-loop
control.
2
Setting range: 0–5000
0.00–P04.51
Description
code
is
used
to
of
the
output
code
is
used
to
-161-
Function parameter list
Default Modify
120.0%
set
the
650
current
350
10.00Hz
0
120.0%
set
the
650
350
10.00Hz