TRAKKER Antares 246X Stationary Terminal User's Manual

Full ASCII Mode for Code 39

With the
using any of these commands:
The last two commands are compatible with the Intermec 95XX terminals. Each
command is described next. For help with the Code 39 configuration command (CB),
see Chapter 8, "Configuration Command Reference."
Note: Use the CB configuration command unless your terminals need to be compatible
with the 95XX terminals in your data collection network.
Command:
Full ASCII configuration command (RB)
Purpose:
Configures the terminal to use Code 39 Full ASCII mode (enabled) or Code 39 Non-
Full ASCII mode (disabled). For a list of ASCII characters, see the "Full ASCII Table"
in Appendix B.
Syntax:
RBdata
Acceptable values for data are:
0
1
Scan:
One of these bar code labels:
Disable Full ASCII Mode
*$+RB0*
*$+RB0*
Command:
Enter Full ASCII Mode reader command
Purpose:
Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by
using a two-character encoding scheme to extend the character set to 128 characters.
For a list of ASCII characters, see the "Full ASCII Table" in Appendix B.
Syntax:
+$
Scan:
Full ASCII
*+$*
*+$*
C-8
application, you can configure Full ASCII mode for Code 39
EM9560.BIN
Code 39 configuration command (CB)
Full ASCII configuration command (RB)
Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader
command (-$)
Disabled
Enabled
nugget
Enable Full ASCII Mode
*$+RB1*
*$+RB1*