Msi - Intermec Trakker Antares 2460 User Manual

Trakker antares 246 series stationary terminal
Hide thumbs Also See for Trakker Antares 2460:
Table of Contents

Advertisement

MSI

Purpose:
Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code.
MSI code includes a start pattern, data characters, one or two check digits, and a stop
pattern.
Syntax:
CNdata
Acceptable values for data are:
First digit:
Second digit:
Default:
Disabled
Scan:
One of these bar codes:
Disable MSI
*$+CN00*
*$+CN00*
MSI Without Check Digits
*$+CN10*
*$+CN10*
MSI With 1 Modulus 10 Check Digit, Discard Check Digit
*$+CN20*
*$+CN20*
MSI With 1 Modulus 10 Check Digit, Transmit Check Digit
*$+CN21*
*$+CN21*
MSI With 2 Modulus 10 Check Digits, Discard Check Digits
*$+CN30*
*$+CN30*
MSI With 2 Modulus 10 Check Digits, Transmit Check Digits
*$+CN31*
*$+CN31*
C d 39
Nugg
0
Disabled
1
No check digits
2
1 modulus 10 check digit
3
2 modulus 10 check digit
0
Discard check digit
1
Transmit check digit
Configuration Command Reference