TRAKKER Antares 246X Stationary Terminal User's Manual

Status Lights Control

Purpose:
From Network:
Keyboard:
Scan:
Or:
7-12
Controls the Modifier, Good Read, and User Defined status lights on the 246X. For a
description of each light, see "Using the Status Lights" in Chapter 1.
$%data
where data must be 8 digits, corresponding to:
Digit
Status Light
1
Modifier
2
Not used
3
Good Read
4
User Defined
5 to 8
Not used
All status lights are turned off when you reset or boot the terminal.
Not supported
All Status Lights Off
*$%0X00XXXX*
*$%0X00XXXX*
All Status Lights On
*$%1X11XXXX*
*$%1X11XXXX*
To turn a specific status light on or off, follow these steps:
1. Scan this bar code label:
Enter Accumulate Mode / Status Lights Control
*+/$%*
*+/$%*
39
nugget
Value
Meaning
0
Off
1
On
X
No change
X
No change
0
Off
1
On
X
No change
0
Off
1
On
X
No change
XXXX
No change