Addendum for 4MB JANUS User
Scan:
2
39nugg
Manuals39
nugg
One of these bar codes:
Disable Code 128
*$+CH0*
*$+CH0*
Enable UCC/EAN Code 128
*$+CH2*
*$+CH2*
Standard Code 128
If you configure Standard Code 128, the reader does not decode Function
Code 1 characters in the first position of a bar code label. Any subsequent
Function Code 1 characters are translated to the ASCII GS character as a
separator for variable length fields.

UCC/EAN Code 128

If you configure UCC/EAN Code 128, the reader decodes a bar code label as
Standard Code 128 unless the first two characters are a start character and a
Function Code 1 character. If the first two characters are a start character and a
Function Code 1 character:
1. The Function Code 1 character is not transmitted.
2. The three symbology ID characters, ]C1, are transmitted.
3. The remaining Code 128 characters are decoded as Standard Code 128.

ISBT Code 128

You can also configure your JANUS device to perform other functions when
you use ISBT Code 128. You can set these parameters with Code 39 bar codes,
through the JANUS configuration application (IC.EXE), or using Code 128
symbology. Spacing between concatenable bar codes must be between 2 and 5
character widths.
For more information on ISBT Code 128, refer to the ISBT 128 Bar Code
Symbology and Application Specification for Labeling of Whole Blood and Blood
Components prepared by the International Council for Commonality in Blood
Banking Automation.
Enable Standard Code 128
*$+CH1*
*$+CH1*
Enable ISBT Code 128
*$+CH8*
*$+CH8*