Download Print this page

Bosch Rexroth IndraMotion MTX 11 VRS Applications Manual page 44

Standard nc operation

Advertisement

42/301
Bosch Rexroth AG
General Operation and Visualization
5.2.4
Drive Configuration for Spindle Torque and Performance
Rexroth IndraMotion MTX 11VRS Standard NC Operation
The display supports a maximum of 10 variants.
If a date is not available, "—" is displayed.
The following table contains a description of the symbols displayed.
Sym‐
bol
Feed symbols
Spindle symbols
Gear symbols
Fig.5-7:
Displayed symbols
The display of spindle torque and performance is done using the SERCOS
parameters S-0-0084 "Torque/power actual value" and S-0-0382 "Intermediate
circuit performance".
These are read either using the cyclic drive telegram (see also S-0-0016 "Con‐
fig. list drive telegram") or directly using the service channel from the drive.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Meaning
Note
G01
Feed
G00
Rapid traverse
G02
Circular interpolation right
Circular interpolation, counter‐
G03
clockwise
G33
Thread cutting
M3
Clockwise rotation
Clockwise rotation, coolant
M13
switched on
M4
Counterclockwise rotation
Counterclockwise rotation, cool‐
M14
ant switched on
M5
Spindle stop
Spindle orientation (positioning
M19
mode)
Manual
Automatic
Idle

Advertisement

loading