Download Print this page

Bosch Rexroth IndraMotion MTX 11 VRS Applications Manual page 248

Standard nc operation

Advertisement

246/301
Bosch Rexroth AG
Extended Functionality
Properties of the Energy Monitor
Components
11.2.2
Commissioning the Energy Monitor
Prerequisites
Configuration of the Energy Monitors - Drives
Rexroth IndraMotion MTX 11VRS Standard NC Operation
The energy monitor shows the power consumption of the
latest ten measurements as bar chart
individual drives as well as
individual auxiliary equipment.
The energy monitor consists of the following sections:
header
main screen and
F-keypads
The energy monitor gets the data to be displayed via the PLC function block
"MT_4EEGuiMonitor". To do so, the respective function block has to be inte‐
grated into the PLC program and wired (also refer to the PLC Programming
Manual).
Furthermore, the energy monitor has to be configured. It is to be started under
"Production data" with <F2>, the configuration menu has to be started with
<F8> and the configuration has to be carried out as described in the following
subchapters.
Fig.11-8:
Configuration of the energy monitor - Drives
Within the "Energy Monitor - Drives" window, all SERCOS drives have to be
entered. To achieve this, the following functions are available:
+: Inserting a new drive
- : Deleting the currently selected drive
DOK-MTX***-NC*OP***V11-AP01-EN-P