138/301
Bosch Rexroth AG
Programming
7.4.2
General Structure of the Editor to Define SD Variables
Editor structure
Input options in the individual col‐
Fig.7-12:
Editor structure
The editor consists of a list with six columns:
●
Identifier
●
Type
●
Memory type
●
Dimension
●
Init
●
Comment
Each column has its individual input options. There are freely editable input
umns
fields and predefined selection lists.
●
Identifier
–
Freely editable SD variable name.
●
Type
–
Selection from a list of all data types defined in the schema files.
●
Memory type
–
Selection between volatile and permanent.
●
Dimension
–
Selection between Channel, Drive and Spindle or
–
freely editable dimension.
●
Init (no entry)
–
Information whether there is an initialization value defined for the
variable in the "SDdatxxx.xml" file.
●
Comment
–
freely editable comment
DOK-MTX***-NC*OP***V11-AP01-EN-P