Tool Management
Information Area
Absolute, Additive, Diameter Value
8.2
Operation
8.2.1
Value Entry
Navigation and Selection of Cells
This part of the table contains data that cannot be edited and which are
used to identify the data sets.
2. Frozen, editable table area:
This part of the table contains data that can be edited and which are nev‐
ertheless used to identify the data sets; therefore, they always have to be
visible.
3. Scrollable table area:
This part of the table contains all other data that can be edited.
The two fixed table areas should be kept as small as possible so that extensive
scrolling is prevented.
Status Line
Fig.8-3:
Status line in the tool list display
The status line of the tool list display is divided into several areas:
Information Area
Additive value entry
List of open windows in this mode
Current language
If a limit value is defined for the tool data element selected in the list using cursor
navigation, the input limits are displayed in the information area.
As a rule, limit definitions can be based on:
data elements in a scheme and/or
tool and data elements in the list configuration
.
The mode "Additive value entry" is shown in the 2nd field by the text "ADD" (see
Entry
chapter "Additive Value Entry" on page
The mode "Absolute value entry" is shown in the 2nd field by the text "ABS".
The mode "Diameter value entry" is shown in the 2nd field by the text "DIA" (see
"Diameter Entry" on page
The fields "Open windows" and "Current language" are filled in by
the system.
To enter a correction value, the desired entry cell of the value first has to be
selected as follows:
Click the mouse on the desired cell.
– or –
Navigate with the <cursor> keys until the desired cell is selected.
The selected cell can be recognized from the dark blue background color.
The selected partial list can be recognized by the light blue background color.