Standard nc operation

Advertisement

136/301
Bosch Rexroth AG
Programming
7.4
Editor to Define SD Variables
7.4.1
Usage
Rexroth IndraMotion MTX 11VRS Standard NC Operation
The selected list is activated. When switching to the "Machine" operating
area, this list is displayed by pressing the F-key "Active variables".
Write variable values
After confirming a prompt, the values of the selected list are transferred to
the control.
In case of error, a list with the occurring errors appears.
If no error occurs, a respective note appears in the status line.
Configuring Functions to Quickly Activate Variable Lists
The configuration of fast functions to quickly activate variable lists is carried out
in IndraWorks Engineering (commissioning). The functions can be applied to
both F-keys and M-keys. To do this, the "Variables" function is assigned to one
key. Either a path or a specific list can be entered in text field "Path or list
name". If only one list is entered, it is displayed as soon as the key is pressed.
If a path is entered, a list of all the variable lists existing in this path is shown
when the key is pressed. When a list is selected, it is immediately displayed.
Interruption of Connection
If the connection to the control is interrupted, all variable editors are closed. If
edited data has not been saved at this point in time, the files are saved on the
hard disk under the same name (including the path) in the directory
"c:\SaveXXXXXXXX".
"XXXXXXXX" stands for the abbreviation of the current date (year/month/day).
Example:
20050614 corresponds to June 14, 2005.
After the connection has been restored, the saved files can be copied to a mount
directory of the control using the Windows Explorer.
This application is used to comfortably define SD variables. The variable defi‐
nition is stored in files of type SDDefxxx.xml.
The defined variables are available in the control if the definition files are saved
in one of these directories:
Root directory of the control
/feprom
/usrfep
Changes in definition files become only effective after an NC restart.