Download Print this page

Bosch Rexroth IndraMotion MTX 11 VRS Applications Manual page 278

Standard nc operation

Advertisement

276/301
Bosch Rexroth AG
Extended Functionality
Determining small diameter
Error
Error causes
Error display
Error recovery
11.6.4
Tolerance Dimension Table
Overview
Layout
In order to determine the large diameter D1, taper relation/setting angle and the
taper length have to be specified in any order. Finally, the large diameter D2 is
entered. If afterwards, the focus leaves the entry field and/or if now, the return
key is pressed, the small diameter will appear in the last but one text box.
Errors are caused in the entry of values and/or expressions. The following cau‐
ses can be considered:
Inadmissible mathematical operations,
Syntax errors and
exceedance of a value range.
In the lower part of the form, an error message appears, either with reference
to the violated value range or as format error. The focus is automatically reset
to the faulty entry field.
Using the <Esc> key, you can reject the latest entry or edit the entry field speci‐
fied in the error message.
Tasks
The tolerance dimension table allows for the determination of an allowance for
a given nominal size and the tolerance field as it can be found as measure in
a drawing. The table is based on the preference tolerances from DIN ISO 286
and/or DIN 7154 and DIN 7155 for the hole basis system and/or the shaft basis
system in the nominal size range from 1 to 500 mm. The following allowances
(in mm) are shown:
Upper allowance,
Medium allowance, and
Lower allowance.
The form for the tolerance dimension table is located on the "Tolerance dimen‐
sion" tab.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation

Advertisement

loading