Bosch Rexroth IndraMotion MTX 11 VRS Applications Manual page 244

Standard nc operation

Advertisement

242/301
Bosch Rexroth AG
Extended Functionality
Type
Class
System error_
Fatal system error*
Error
→ Critical error
Critical error
Low-priority system error*
→ Error
Warning
System warning
by the user program
System information
Information:
Programmed note
General
Input error
Operating errors
User Reactions on Errors and Messages
Error Messages
Error message number and message
text number
(#9)
Invalid value
The value NUL cannot be assigned to a
permanent CPL variable.
The old value is restored.
(#8)
File is write-protected.
(#23)
It is not possible to set the current varia‐
ble value. (IVariable::SetVarValue)
(#86)
It is not possible to set the current varia‐
ble value. (IVariable::UndefVar)
Description
Internal error causing operation stop of the control.
The NC-Analyzer closes automatically after confirmation.
Internal error causing a part of the control not being functional anymore.
The user can decide whether to continue working with the NC-Analyzer.
Warning from a part of the NC-Analyzer, such as failed to load config‐
uration data
such as number of breakpoints exceeded.
Programmed note by the NC program:
(MSG)
PRN'(0,....)
such as variable value invalid
*)
In case of system errors, service must be notified as well if necessary.
Fig.11-6:
Error classes: NC-Analyzer
The following measures can be cases in case of information, messages, warn‐
ings and "low-priority" system errors:
Discard messages or errors as long as it is still possible to work with the
NC-Analyzer or as long as information on error recovery is provided.
Restart the interface
Contact service
In case of "critical" system errors, the only options left may be:
Restart the interface
Contact service
Cause
Messages about the attempt to enter some incorrect values
Input value of the edited variable does
not correspond to the variable type
The value NUL cannot be assigned to a
permanent CPL variable.
Messages about some unauthorized user actions
Attempt to save a write-protected file.
Attempt to edit an individual element of a
CPL constant.
Attempt to edit a complete CPL constant. Continue.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Recommended to the user
Enter a value that corresponds to the re‐
quired variable type.
(See also CPL programming manual).
Enter a valid value for the permanent
CPL variable or accept the old value.
Continue. (It is not possible to save write-
protected files).
Continue.