Download Print this page

Bosch Rexroth IndraMotion MTX 11 VRS Applications Manual page 39

Standard nc operation

Advertisement

DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Meaning
Channel state
The status of the active NC
channel is shown as symbol
and text in this area.
Test mode
Channel settings
Channel in waiting state
Symbol Explanation
Ready
Running
Stop
Prepared
Malfunction
Inactive
Control Reset
The symbol indicates that a channel-specific test function (dry run), test feeding and/
or test rapid traverse is active.
The signal indicates that the "Optional stop" function is active.
The signal indicates that the "Block skip (M01)" function is active.
Waiting states that cannot be specified by a separate bitmap are displayed using
this bitmap.
This bitmap is also shown if more than one waiting state has occurred. All waiting
states that have occurred are displayed in the tooltip by moving the mouse over the
symbol or by pressing the F-key in the channel dialog.
Dwell time
Auxiliary function with acknowledgement obligation
Transfer inhibit
Channel feed = 0
Program stop (M0/M1)
Feed stop
Feed lock
Fig.5-1:
Visualization symbols
Bosch Rexroth AG
General Operation and Visualization
37/301

Advertisement

loading