Error message number and message
text number
(#43)
It is not possible to set the Dry Run mode.
(IDryRunMode::SetDryRunMode)
Messages regarding problems when setting breakpoints and variables for monitoring purposes
(#12)
The number of breakpoints is restricted.
It is not possible to activate a breakpoint
or set a new one.
(#2)
It is not possible to perform the requested
operations in the "Breakpoint" dialog.
(#14)
It is not possible to create or activate a
breakpoint.
(#89)
It is not possible to activate a breakpoint
or to set an active breakpoint because
the current NC mode is not the NC-Ana‐
lyzer mode.
(#92)
It is not possible to set an active break‐
point because the Dry Run mode is not
set.
(#13)
The number of variables to be watched
and breakpoints on variables are restric‐
ted.
It is currently not possible to select an‐
other variable for asynchronous monitor‐
ing or to set a breakpoint on a variable.
(#121)
The breakpoint on the variable "Variable
name" has been reached.
The access mode is: Write!
(#122)
The breakpoint on the variable "Variable
name" has been reached.
The access mode is: Read-only!
Cause
Attempt to cancel the DryRunMode while
the NC-Emulator is running.
The number of breakpoints was excee‐
ded.
Attempt to activate breakpoints of an in‐
active program using the "Breakpoints"
dialog.
Attempt to modify the access mode of
breakpoints on variables of an inactive
flow program.
Attempt to set a breakpoint in the inactive
flow program.
Attempt to either activate or set an active
breakpoint if the NC-Analyzer mode was
not set.
Attempt to set the active breakpoint in the
inactive program. NC-Analyzer mode
was not set.
Attempt to set the active breakpoint using
the mouse if DryRunMode was not set.
The number of monitored variables or
breakpoints on variables was exceeded.
Messages to reach breakpoints on variables
Interruption of program execution at
breakpoint.
Interruption of program execution at
breakpoint.
Bosch Rexroth AG
Extended Functionality
Recommended to the user
Continue since the DryRunMode is al‐
ways set when the NC-Emulator is run‐
ning.
Delete or deactivate either one or several
active breakpoints.
Continue or select the program with the
breakpoint(s) desired as active and
execute the desired action.
Continue or select the program with the
breakpoint(s) desired as active and
execute the desired action.
The breakpoint remains inactive (even if
the flow program becomes active).
Set the NC-Analyzer mode.
Execute the desired actions with break‐
points.
Select the desired program as active
one. Set the NC-Analyzer mode.
Carry out the desired actions with break‐
point(s).
Set DryRunMode (NC-Analyzer mode
should also be set). Then set the break‐
point.
Delete as many variables from the list of
asynchronous monitorings as necessa‐
ry.
Delete or deactivate as many break‐
points on the variables as necessary.
Continue.