12-182 Star Remote System card replacement procedures
NTTR77
in a STAR
(continued)
15
16
17
18
19
20
21
22
23
24
25
297-8353-550 Standard 05.01 March 2001
To demount the tape drive, type
>DEMOUNT T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 26.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
To access the disk utility level of the MAP, type
>DSKUT
and press the Enter key.
To list the IOC file names into your user directory, type
>LISTVOL volume_name ALL
and press the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 17
To leave the disk utility, type
>QUIT
and press the Enter key.
Go to step 26.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
To access the disk utility level at the MAP display, type
>DISKUT
and press the Enter key.
To list the SLM file names into your user directory, type
>LV CM;LF volume_name
and press the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 22
To leave the disk utility, type
>QUIT