Nortel DMS-100 Series Maintenance Manual page 299

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing a PM STAR major alarm
At the MAP terminal
1
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
2
To access the PM level of the MAP display, type
>PM
and press the Enter key.
3
To identify the STAR with faults, type
>DISP STATE ISTB STAR
and press the Enter key.
4
To post the STAR with the alarm condition, type
>POST STAR STATE ISTB
and press the Enter key.
5
To determine the fault indicators, type
>QUERYPM FLT
and press the Enter key.
If fault indicated is
ringing generator (RG)
CBsy (C-side busy)
SysB
ManB
drawer fault
fuse card fault
one or both NTTR73AA univer-
sal maintenance pack (UMP)
cards are out of service
fuse card failure
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
major
Do
step 6
step 10
step 17
step 18
step 21
step 21
step 21
step 21
11-33
PM STAR
(continued)

Hide quick links:

Advertisement

Table of Contents
loading