Nortel DMS-100 Series Maintenance Manual page 398

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12-50 Star Remote System card replacement procedures
NT6X99
in a STAR or RLD
Replacing an NT6X99 card in a STAR or RLD
At your current location
1
At the MAP display
2
3
4
5
297-8353-550 Standard 05.01 March 2001
(continued)
Get a replacement card. Make sure that replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
To access the LTP level of the MAP and post the line associated with the card
to be replaced, type
>MAPCI;MTC;LNS;LTP;POST L site frame unit lsg ckt
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the faulty card (0 to 511)
unit
is 0 for the STAR
lsg
is the number of the line subgroup with the faulty card (0 to 35)
ckt
is the number of the circuit associated with the faulty card (0 to 31)
Example of a MAP display:
LCC PTY RNG .....LEN..........DN
RES
REM1 00 0 03 03
Check the status of the posted line.
If the line status is
manual busy (MB)
not MB
To busy the line, type
>BSY
and press the Enter key.
Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return to this point.
STA F S LTA TE RESULT
IBERT MB
Do
step 5
step 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents