Nortel DMS-100 Series Maintenance Manual page 219

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Table 7-13 Star Module log reports (Sheet 2 of 4)
Log
report
Reason for output
PM181
State change or process
failure
PM182
RLD link status changed
to ManB.
PM183
RLD link status changed
to SysB.
PM184
RLD link status changed
to RTS.
ISDN100
RLD detects a terminal
that is not available for
message traffic.
Star Remote System manual maintenance 7-15
Meaning
This log is output for the
following reasons
RLD state changed
— for ISTb and SysB, a
failure reason text is
output
— for ISTb, a log is
output for every
reason added or
removed
switch bank is completed
whether successful or not
RLD test failed
file is loaded to the RLD or
the load attempt has failed
static data updated failed
or was successful
RLD enters or exits
overload (congestion)
The state of the RLD link
changes to ManB.
The state of the RLD link
changes to SysB.
The state of the RLD link
changes to RTS.
An ISDN terminal does not
support traffic.
DMS-100 Family NA100 Star Remote System XPM15 and up
Action
For RLD state changes to
ISTb or SysB, switch
bank failure, static data
download failure, or
congestion entry proceed
according to failure
reason.
No action is required if
the file loads
successfully.
If the load operation fails,
proceed according to the
failure reason.
No action required.
No action required.
No action required.
Determine the reason
why the terminal is not
available for message
traffic. Contact the next
level of maintenance.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents