5-14 ESA maintenance overview
8. The DMS-100 CC returns the Star Hub to service.
ESA manual exit
A manual exit is an exit from ESA mode that operating company personnel
start at the STAR MAP level through the RTS command. A manual exit is
required if one of the following conditions are present:
Operating company personnel override a time-out value different from zero to
start a manual exit. Operating company personnel busy the Star Hub units at
the STAR MAP level to override the time-out value. Personnel must use the
FORCE option with the BSY command.
The following steps describe the manual exit sequence:
1. The C-side communications between the DMS-100 CC and the Star Hub
2. The DMS-100 CC determines the Star Hub is in ESA mode.
3. The DMS-100 CC queries the Star Hub for the number of active calls.
4. The DMS-100 CC displays the number of active calls on the MAP display
5. If operating company personnel confirm the ESA exit, the DMS-100 CC
6. If operating company personnel do not want to continue with the ESA
7. The ESA software in the RCP perform exit operations.
8. The ESA software in the RCP card returns the Star Hub to normal
9. The ESA software sends operational measurements, peg counts, and the
10. The DMS-100 CC returns to service the Star Hub.
11. The receiver is off-hook.
Tones during ESA mode
The UMP card provides the ESA call progress tones and detection of DTMF
dialing. Though call progress tones are partially supported, since no features
are supported during ESA, many of the call progression tones are not required.
297-8353-550 Standard 05.01 March 2001
CC. This information appears in the PM171 log. The system generates
the PM181 log if the ESA exit has problems.
Both units of the Star Hub are in a ManB state.
RLCM_XPMESAEXIT office parameter time-out value is set to zero.
restore.
and queries to confirm the operating company personnel if ESA exit.
sends the ESA exit request to the ESA software in the RCP.
exit, the Star Hub is left ManB. The Star Hub remains in ESA mode.
operations.
reason the Star Hub dropped into ESA mode to the DMS-100 CC. This
information appears in the PM171 and PM181 logs.