LOADPM command
When ESA data needs to be downloaded to in-service Star Hub units, the
following commands can be entered, depending on requirements, for updating
ESA data
QUERYPM command
When the QUERYPM command is entered at the MAP terminal, information
about ESA and the UMP cards are displayed, in addition to the regular
information provided with the QUERYPM command response. An example
of a MAP display showing the system response to the QUERYPM command
follows.
Figure 6-3 Example of a QUERYPM command at the STAR level
CM
MS
.
.
STAR
0
Quit
2
Post_
3
ListSet
4
SwRg_
5
Trnsl_
6
Tst_
7
Bsy_
8
RTS_
9
Offl
10 LoadPM_
11 Disp_
12 Next
13
14 QueryPM
15
16 ILD
17 RLD
18 RLDCarr
userid
TIME
hh : mm>
An example of the QUERYPM FLT command that displays the Star Hub or
unit-related ISTb reasons and any UMP-related ISTb reasons follows.
LOADPM PM CC ESADATA to update the ESA data for the entire Star
Hub
LOADPM UNIT unit_no CC ESADATA to update the ESA data in a
specific unit of the posted Star Hub
IOD
Net
PM
CCS
.
.
4 SysB
M
SysB
PM
4
STAR
0
STAR REM1 00 0
ISTb
Unit 0:
ISTb
Unit 1:
ManB
Drwr:
11 11 11 11 11 22 22 22 22 22 33 33 33
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
.. .. –– –– –– –– –– –– –– –– –– –– –– –– –– –– –– ––
QUERYPM
PM Type:
STAR Int. No.:5 Status index: 5 Node_No: 42
STAR REM1 00 0 Memory size – Unit 0: 8M , unit 1: 8M
ESA Equipped: No, Intraswitching is Off
Loadnames: LCMINV – RSRD0811, Unit 0: NLCN0700
Node Status: {OK, FALSE}
UNIT 0 Status: {OK, FALSE}
Unit 1 Status: {MAN_BUSY, FALSE}
Site Flr RPos
Bay_id
STAR
00
A00
SRHE 00
Services: NEUTRAL
UMP 0 OffL Loadnames: RMPCKT – RSRD0811 Real * Unknown
This PM is: STAR
DMS-100 Family NA100 Star Remote System XPM15 and up
Star Remote System user interface 6-9
Lns
Trks
.
.
.
ManB
OffL
0
10
0
0
Links_OOS: CSide 0 PSide 0 UMP OOS:0
/RG: 0
/RG: 0
Shf Description
00
STAR 00 00
Ext
Appl
.
.
CBsy
ISTb
3
3
0
1
RG
Pref 0 InSv
Stby 1 InSv
Slot
EqPEC
NT8602
InSv
3
1