LOADRLD command
When one bank of the Star Module needs to be loaded, enter one of the
following commands
LOADRLD CC to load the posted Star Module from the comuting module
(CM)
LOADRLD MATE to load the inactive bank of the posted Star Module
from its active bank
The optional ALL parameter can be entered with the previous commands to
load all Modules in a posted set that are connected to the same STAR.
The optional NOWAIT parameter allows operating company personnel to run
the LOADRLD activity in the background while performing other operations
at the MAP terminal.
Note: The RLD loading progress is output in the status line for STAR Unit
0. The system identifies the RLD Stby bank as "loading" when loading
occurs.
QUERYPES command
The QUERYPES command at the RLD level displays alarm information about
the posted Star Module. The QUERYPES command can be entered with no
parameters or with the FLT (fault) parameter.
when no parameter is used with the QUERYPES command, the system
responds with the Module PES condition and lists all the alarms
the FLT parameter displays only the fault alarms
in all alarms but the DOOR alarm, a period (.) means no alarm and "F"
means fault
in the DOOR alarm, a period (.) means door closed and "O" means open
door
The following figure provides an example of the QUERYPES command.
Star Remote System user interface 6-19
DMS-100 Family NA100 Star Remote System XPM15 and up