Nortel DMS-100 Series Maintenance Manual page 378

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12-30 Star Remote System card replacement procedures
NT6X54
in a STAR
(continued)
Replacing an NT6X54 card in an STAR
At your current location
1
2
3
At the MAP terminal
4
297-8353-550 Standard 05.01 March 2001
If you are entering this procedure because of a loss of power in the STAR's
NTTR77AA RCP card, check logutil for PM181 log with reason text of:
DCC BIC Looparound and go to step 12.
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
If you were directed to this procedure from an alarm clearing procedure in this
manual, go to step 12. Otherwise, continue with step 4.
To access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the STAR, type
>MAPCI;MTC;PM;POST STAR site frame unit
and press the Enter key.
where
site
is the site name (alphanumeric) of the STAR
frame
is the frame number (0 through 511) of the STAR
unit
is 0 for the STAR
Example of a MAP display:
ATTENTION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents