11-64 Star Remote System alarm clearing procedures
PM STAR RG
critical
(continued)
Clearing a PM STAR RG critical alarm
You should be entering this procedure from the PM system level alarm
clearing procedure step that identified a STAR-associated fault.
At the MAP terminal
1
2
3
4
297-8353-550 Standard 05.01 March 2001
Silence the alarm by typing
>MAPCI;MTC;PM;SIL
and pressing the Enter key.
Identify the faulty STAR by typing
>DISP STATE ISTB STAR
and pressing the Enter key.
Example of a MAP response:
ISTb
STAR REM1 00 0
Post the ISTb STAR identified in step 3 by typing
>POST STAR site frame unit
and pressing the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the number of the frame (00 to 511)
unit
is 0 for the STAR
Example of a MAP display:
SysB
ManB
PM
0
0
STAR
0
0
STAR REM1 00 0 Istb Links_OOS: CSide 0 PSide 0 UMP OOS:0
Unit 0:
SysB
Unit 1:
ISTb
Drwr:
11 11 11 11 11 22 22 22 22 22 33 33 33
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Check for fault indicators by typing
>QUERYPM FLT
and pressing the Enter key.
ATTENTION
OffL
CBsy
2
0
2
0
/RG: 0
/RG: 0
ISTb
InSv
1
12
1
9
RG:
Pref 0 ISTb
Stby 1 ISTb