Nortel DMS-100 Series Maintenance Manual page 324

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-58 Star Remote System alarm clearing procedures
PM STAR
minor
(continued)
52
53
54
55
56
297-8353-550 Standard 05.01 March 2001
star_unit
is the STAR unit to be returned to service (0 or 1)
If RTS
passed
failed
The card list identifies the possible cards with faults. Replace the cards one
at a time in the order listed. Go to the next step as indicated in the following
table.
If last card on list has
not been replaced
been replaced
To access the UMP level of the MAP, type
>MAPCI;MTC;MTCNA;TSTEQUIP;POST UMP
and press the Enter key.
Identify the UMP cards that are in the STAR in an alarm state. To identify the
cards, type
>HOST STAR site frame unit
and press the Enter key.
where
site
is the site name of the STAR (alphanumeric)
frame
is the frame number of the STAR (0-511)
unit
is 0 for the STAR
Example of a MAP response:
PM
MTE
STAR REM
1 0
UMP 0
Use the NEXT command to cycle through the UMPs until the SysB UMP
appears.
To busy the UMP card in the SysB state, type
>BSY
and press the Enter key.
To test the posted UMP card, type
>TST
Do
step 61
step 59
Do
step 60
step 59
STATE
SysB