Nortel DMS-100 Series Maintenance Manual page 394

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12-46 Star Remote System card replacement procedures
NT6X76
in a STAR or RLD
8
9
At the MAP terminal
10
11
12
297-8353-550 Standard 05.01 March 2001
(continued)
e
Pull the extractor away from the drawer and the card will become
unplugged from its socket on the drawer backplane.
f
Continue pulling the card with the extractor until the card is clear of the
shroud.
g
Insert the card removed into the ESD container and store using local
procedures.
To replace the card with faults, follow these substeps:
a
Remove the replacement card from the ESD container.
b
Slide the card in the shroud guide slots toward the drawer backplane.
c
Hold the front cover of the line drawer with your left hand to steady it.
d
Grasp the top and bottom edges of the card with the fingers of your right
hand.
e
Push the card toward the backplane until it plugs fully into the backplane
socket.
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
To test the NT6X76 line card, type
>DIAG
and press the Enter key.
If DIAG
passes
fails
To return the NT6X76 card to service, type
>RTS
and press the Enter key.
If RTS
passes
fails
Send any faulty cards for repair according to local procedure.
Do
step 14
step 10
Do
step 11
step 15
Do
step 12
step 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents