10-12 Star Remote System recovery procedures
Star Hub recovery procedure
28
29
30
31
32
297-8353-550 Standard 05.01 March 2001
(continued)
If load
is not sucessfull in one unit
is not sucessfull
To again try to return the STAR to service, type
>RTS PM
and press the Enter key.
If return to service for either unit
is sucessfull
is not sucessfull
Contact your maintenance support group for additional instructions in
clearing this fault.
Go to the "Star Remote System card replacement procedures" to replace the
first (or next) card on the card list. Notify outside plant personnel of the card
to be changed. Go to step 26 when the last card is replaced.
To try to load the STAR unit, type
>LOADPM UNIT star_unit
where
star_unit
is the STAR unit (0 or 1) that failed to load in step 27
If load is
sucessfull
not sucessfull
To test the STAR unit, type
>TST UNIT star_unit
where
star_unit
is the STAR unit (0 or 1) to be tested
If test
passes
fails, and the system produces a
card list
fails, but the system does not
produce a card list
Do
step 31
step 29
Do
step 34
step 29
Do
step 32
step 29
Do
step 33
step 24
step 29