and press the Enter key.
If TST
passed
failed
failed and a load failure is re-
ported
57
To load the UMP card, type
>LOADTE
and press the Enter key.
58
To return to service the posted UMP card, type
>RTS
and press the Enter key.
If RTS
passed
failed
59
Contact your maintenance support group for additional instructions in
clearing this fault.
60
Go to the "Star Remote System card replacement procedures" in this manual
to replace the first (or next) card on the card list. When the card is replaced,
return to the appropriate step in this procedure as indicated here.
If you are clearing
drawer faults in a Star Hub
drawer faults in an RLD
all other alarms
UMP with faults
61
You have correctly completed this procedure. If additional alarms are
displayed, go to the appropriate alarm clearing procedure in this manual.
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
minor
Do
step 58
step 60
step 57
Do
step 61
step 59
Do
step 19
step 25
step 50
step 56
11-59
PM STAR
(end)