If
there are blown fuses
At the MAP terminal
19
To busy the STAR that was offlined in step 5, type
>BSY PM
and press the Enter key.
20
To return to service the STAR, type
>RTS PM
and press the Enter key.
If RTS
passes
fails and a card list appears
(an alarm condition exists)
21
Send any faulty cards for repair according to local procedure.
22
Record the following items in office records:
•
date the card was replaced
•
serial number of the card
•
indications that prompted replacement of the card
Proceed to step 25.
23
Get additional help by contacting the personnel responsible for a higher level
of support.
24
If alarms are displayed, go to the appropriate alarm clearing procedure in this
manual.
25
You have correctly completed this procedure.
Star Remote System card replacement procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
in a STAR
Do
step 23
Do
step 21
step 24
12-167
NTTR75
(end)