9-4 Star Remote System power up and power down procedures
Procedure 9-5 Powering down the Star Module
To power down the Star Module, use the following steps:
1
2
3
4
5
6
297-8353-550 Standard 05.01 March 2001
CAUTION
Loss of service
This procedure is reserved for extreme conditions such as
impending natural disasters. It will result in a complete
loss of subscriber service.
Post the Star Module (RLD).
Busy the Star Module.
Remove power from the busied Star Module by setting circuit breaker on the
dc panel to OFF.
Remove ac power from the Star Module as follows:
if an indoor wall-mounted SRME, remove power at the local ac power
panel
if an outdoor pad or pole-mounted SRMO, set the Rectifier circuit breaker
on the ac panel to the OFF position. Then set the Main circuit breaker on
the ac panel to the OFF position.
The Star Module is now powered down.
You have correctly completed this procedure.