12-88 Star Remote System card replacement procedures
NTMX81
in a STAR
(continued)
Replacing an NTMX81 card in a STAR
At your current location
1
2
At the MAP terminal
3
SysB
PM
STAR
STAR REM1 00 0
Unit 0:
Unit 1:
Drwr:
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
4
297-8353-550 Standard 05.01 March 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for checking
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
To access the PM level and post the STAR, type
>MAPCI;MTC;PM;POST STAR site frame unit
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the faulty card (0 to 511)
unit
is 0 for the STAR
Example of a MAP response:
ManB
OffL
0
0
0
0
ISTb
Links_OOS: CSide 0 PSide 0 UMP OOS:0
ISTb
InSv
11 11 11 11 11 22 22 22 22 22 33 33 33
Determine the slot location of the NTMX81 with faults.
If the NTMX81 is in an NTTR87 in
slot
8 or 16 (C-side DS-1 links to
host PM)
9, 10, 14, or 15 (P-side DS-1
links to Star Module)
CBsy
ISTb
2
0
2
0
/RG: 0
/RG: 0
Do
step 5
step 11
InSv
1
12
1
9
RG:
Pref 0 InSv
Stby 1 InSv

Hide quick links:

Advertisement

Table of Contents
loading