Advertisement

SMC DIP switch S3 settings
Mode
DS-1 extended
superframe (ESF)
binary eight bit zero
substitution (B8ZS)
code suppression
13
14
15
At the MAP terminal
16
Star Remote System card replacement procedures
DIP switch settings
S3-1
S3-2
S3-3
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
On
Off
Replace the SMC card.
Power up the RLD by performing the following steps:
a
Provide ac power to the RLD as follows.
if the enclosure is an indoor wall-mounted SRME, supply power at
the local ac power panel
if the enclosure is an outdoor pad or pole-mounted SRMO, set the
Main circuit breaker on the ac panel to the ON position. Then set the
Rectifier circuit breaker on the ac panel to the ON position.
reconnect the battery connector.
b
Set the circuit breaker on the dc panel to ON.
c
Note that the green Power On LED is lit. Make sure no alarm condition is
indicated by the LEDs on the SMC card.
d
The RLD is now powered up.
Wait at least 3 minutes for the Star Module to power up and become stable
before continuing to the next step.
Load the standby (Stby) flash memory bank on the NTTR70 card. To load the
Stby bank, type
>LOADRLD CC
and press the Enter key.
If LOADRLD
passes
fails
DMS-100 Family NA100 Star Remote System XPM15 and up
in an RLD
Distance to Star Hub
D3-4
Feet
Off
0-133
On
133-266
Off
266-399
On
399-533
Off
533-655
Do
step 17
step 24
12-137
NTTR70
(continued)
Meters
0-41
41-81
81-122
122-163
163-200