and press the Enter key.
If the load file in the RLD and the
load file entered in table LCM-
DRINV and the load identified in
office records
match
do not match
29
To access table LCMDRINV, type
>TABLE LCMDRINV
and press the Enter key.
30
To position on the tuple for the RLD that has faults, type
>POS STAR site frame unit
and press the Enter key.
where
site
is the site name of the STAR (alphanumeric)
frame
is the frame number of the STAR (0-511)
unit
is 0 for the STAR
31
To change the tuple for the RLD that contains the load, type
>CHA DRWRTAB drwrtab_no
and press the Enter key.
where
drwrtab_no
is the RLD drawer number plus 1 (for example, if the RLD drawer to be
changed is 8, then enter 9)
32
Retype the tuple with the correct loadname information.
Note: The name entered must be present in table PMLOAD.
Example of a MAP response:
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
minor
Do
step 23
step 35
11-51
PM STAR