Replacing an NT6X71 card in a STAR or RLD
At your current location
1
Get a replacement card. Mke sure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
At the MAP terminal
2
To access the line test position (LTP) level of the MAP display and post the
line associated with the card to be replaced, type
>MAPCI;MTC;LNS;LTP;POST L site frame unit lsg ckt
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the faulty card (0 to 511)
unit
is 0 for the STAR
lsg
is the number of the line subgroup with the faulty card (0 to 35)
ckt
is the number of the circuit associated with the faulty card (0 to 31)
Example of a MAP display:
LCC PTY RNG .....LEN.........DN
RES
REM1 00 0 03 03
3
Check the status of the posted line.
If the line status is
ManB
not ManB
4
To busy the line, type
>BSY
and press the Enter key.
5
Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return here.
Star Remote System card replacement procedures
in a STAR or RLD
DMS-100 Family NA100 Star Remote System XPM15 and up
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4
12-39
NT6X71
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents