Nortel DMS-100 Series Maintenance Manual page 372

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12-24 Star Remote System card replacement procedures
NT6X53
in a STAR
(continued)
Replacing an NT6X53 in a STAR
At your current location
1
2
At the MAP display
3
STAR
Unit 0:
Unit 1:
DRwr:
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
4
297-8353-550 Standard 05.01 March 2001
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
To access the PM level of the MAP and post the STAR, type
>MAPCI;MTC;PM;POST STAR site frame unit
and press the Enter key.
where
site
is the name of the STAR site
frame
is the frame number of the STAR (0 to 511)
unit
is 0 for the STAR
Example of a MAP display:
SysB
ManB
PM
0
0
STAR
0
0
Rem1
OO O ISTb
InSv
Mtce TakeOver
SysB
Mtce
11 11 11 11 11 22 22 22 22 22 33 33 33
To busy the STAR unit containing the faulty card, type
>BSY UNIT STAR_unit
and press the Enter key.
where
star_unit
is the STAR unit (0 or 1) to be busied
Example of a MAP display:
OffL
CBsy
0
0
0
0
Links_OOS: CSide 0 PSide 0
/RG:
0
/RG:
0
ISTb
InSv
1
130
1
10
RG:
Pref 0 InSv
Stby 1 InSv

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents