6-40 Star Remote System user interface
Table 6-21 Subscriber loop testing capabilities of the UMP or LMU (Sheet 2 of
2)
Feature
Capacitance measurement
DC signature measurement
Note: x means testing capability supported by the UMP or LMU.- means testing
capabililty not supported by the UMP or LMU.
LTPDATA level
The following table contains a list of LTPDATA commands used to maintain
control position data, posted set information, system status updates, and
perform additional maintenance action on lines in the control position.
Table 6-22 LTPDATA level commands
Command
Supported?
QUIT
Yes
POST
Yes
SUSTATE
Yes
LOOPBK
Yes
BERT
Yes
EQUIP
(see
No
note)
CONNECT (see
No
note)
BPVO (see note)
No
HOLD
Yes
NEXT
Yes
BERTTIME
Yes
(non-menu)
Note: These tests are only applicable to Datapath lines.
297-8353-550 Standard 05.01 March 2001
ISDN
x
x
Line types
ISDN
ISDN
ISDN, MBS
ISDN
ISDN
Not applicable
Not applicable
Not applicable
All
All
ISDN
POTS
x
x (only on lines
connected to the
Star Module)
Configuration dependent?
No
No
No
Yes
Yes
Not applicable
Not applicable
Not applicable
No
No
No