11-14 Star Remote System alarm clearing procedures
Ext FSP
SRHE frame major
53
54
55
56
57
58
59
60
297-8353-550 Standard 05.01 March 2001
(continued)
Use the following table to identify which circuit breaker located on the FSP, is
associated with the power converter in the unit with a lit Converter Fail LED.
IfSlot number
03, in unit 0
05, in unit 0
18, in unit 1
20, in unit 1
Determine if the associated circuit breaker is ON or OFF.
If the circuit breaker is
ON
OFF
Set the circuit breaker you have just identified to ON.
If the circuit breaker
turns OFF, and the Converter Fail LED is lit
remains ON, and the Converter Fail LED is lit
remains ON, and the Converter Fail LED is not lit
Set the circuit breaker to OFF.
Replace the converter by performing the appropriate procedure in "Star
Remote System card replacement procedures" in this manual. When you
have completed the procedure, return to this point.
Determine if there are bent or short-circuited pins on the backplane of the
shelf.
If there are
bent or short-circuited pins
no bent or short-circuited pins
Set the circuit breaker to OFF.
Straighten or replace bent or short-circuited pins. Then go to step 54.
DoCircuit breaker number
PS00, Slot 3
PS01, Slot 5
PS11, Slot 18
PS10, Slot 20
Do
step 56
step 55
Do
step 57
step 56
step 63
Do
step 59
step 61