6-6 Star Remote System user interface

PM states

The following table lists PM states seen at the MAP terminal.
Table 6-3 Overview of PM states
PM state
Central side busy
In service
In-service trouble
Manual busy
Offline
System busy

STAR level user interface

The STAR level is used to monitor and maintain the Star Hub.
The Star Hub is integrated into the peripheral module (PM) level MAP display
using the STAR level. The following figure shows a typical response at the
MAP display when posting a Star Hub.
297-8353-550 Standard 05.01 March 2001
Code
Description
CBsy
PM is unable to communicate with the central control (CC)
because the network interface links, used to carry messages
between PM and the DMS SuperNode network, are unavailable.
InSv
PM is in service and able to support any intended process, such
as call processing.
ISTb
PM is in service but has a minor fault.
ManB
PM is busy because the BSY command is entered at the MAP
terminal.
Offl
PM is removed from service to allow commissioning tests or to
temporarily hold the Star Hub out of service.
SysB
PM is removed from service by system maintenance.