61
Set the circuit breaker to ON.
If the converter fail LED is
lit
not lit
62
Replace the NTTR74AA alarm card by performing the appropriate procedure
in "Star Remote System card replacement procedures" in this manual. When
you have completed the procedure, return to this step.
63
Determine if the Major alarm LED on the FSP is lit.
If the Major alarm LED is
lit, and there are more lit fail
LEDs or blown fuses
lit, and there are no more lit fail
LEDs or blown fuses
not lit
At the MAP terminal
64
To access the EXT level of the MAP display, type
>MAPCI;MTC;EXT
and press the Enter key.
65
Determine if an FSP alarm is present.
If an FSP alarm is
present, and you have not accessed all the frames
with an FSP alarm
present, and you have accessed all the frames with an
FSP alarm
not present
66
Perform the appropriate procedure for the type of frame that has the FSP
alarm. When you have completed the procedure, return to this step.
67
Go to the "Star Remote System alarm clearing procedures" in this manual
and perform the talk battery alarm clearing procedure. Return to this step
when completed.
68
For additional help, contact the personnel responsible for the next level of
support.
69
You have correctly completed this procedure.
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
SRHE frame major
Do
step 62
step 63
Do
step 2
step 68
step 64
Do
step 66
step 68
step 69
11-15
Ext FSP
(end)