Nortel DMS-100 Series Maintenance Manual page 339

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

SysB
PM
0
STAR
0
STAR REM1 14 0
Unit 0:
ISTb
Unit 1:
ISTb
Drwr:
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45 Stby 1 InSv
.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
4
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
Example of a MAP display:
QUERYPM FLT
Node inservice troubles exist:
One or both Units inservice trouble
STAR
UNIT 0
Ringing Generator Failure:Ring Generator ANI/COIN Fault
STAR
UNIT 1
Ringing Generator Failure:Ring Generator in Excess load
If ringing generator (RG) failure
is
indicated
not indicated
At the STAR site
5
Make a visual inspection of the ringing generator. Check to see if the LED is
lit.
If the LED is
lit
not lit
Star Remote System alarm clearing procedures
ManB
OffL
0
2
0
2
ISTb
Links_OOS: CSide 0 PSide 0 UMP OOS:0
/RG: 0
/RG: 0
11 11 11 11 11 22 22 22 22 22 33 33 33
Inservice troubles Exist:
Inservice Troubles Exist:
DMS-100 Family NA100 Star Remote System XPM15 and up
PM STAR RG
major, minor
CBsy
ISTb
InSv
0
1
0
1
RG:
Do
step 8
step 5
Do
step 6
step 8
11-73
(continued)
12
9
Pref 0 ISTb