16
Determine if the STAR is equipped with emergency stand-alone (ESA) by
typing
>QUERYPM
and pressing the Enter key.
Example of a MAP response:
PM Type:
STAR REM1 00 0 Memory size – Unit 0: 8M , unit 1: 8M
ESA Equipped: No, Intraswitching is Off
Loadnames: LCMINV – RSRD0811, Unit 0: NLCN0700
Node Status: {OK, FALSE}
UNIT 0 Status: {OK, FALSE}
Unit 1 Status: {MAN_BUSY, FALSE}
Site Flr RPos
STAR
00
Services: NEUTRAL
UMP 0 OffL Loadnames: RMPCKT – RSRD0811 Real * Unknown
This PM is: STAR
If STAR is
equipped with ESA
not equipped with ESA
17
Determine if the STAR is in ESA by manually checking for dial tone at the
remote. A PM alarm appears on the MAP screen indicating the STAR is in
ESA. PM106 logs are generated when the PM goes SysB. PM110 logs are
generated for DS-1 link alarms. PM128 logs are generated when there is a
change of state in the PM.
If the STAR
has dial tone
does not have dial tone
Star Remote System alarm clearing procedures
CAUTION
Failing to allow sufficient time may cause false alarm indication.
Allow 3 to 5 minutes for the system to clear the alarm before
proceeding to the next step.
STAR Int. No.:5 Status index: 5 Node_No: 42
Bay_id
Shf Description
A00 HUB 00
00
STAR 00 00
DMS-100 Family NA100 Star Remote System XPM15 and up
critical
Slot
Do
step 17
step 24
Do
step 18
step 24
11-23
PM STAR
(continued)