10-6 Star Remote System recovery procedures
Star Hub recovery procedure
Star Hub recovery procedure
At the MAP display
1
2
3
4
5
6
297-8353-550 Standard 05.01 March 2001
(continued)
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
CAUTION
Failing to allow sufficient time may cause false alarm indication.
Allow 3 to 5 minutes for the system to clear the alarm before
proceding to the next step.
To access the peripheral module (PM) level of the MAP display, type
>PM
and press the Enter key.
To identify a STAR with faults, type
>DISP STATE CBSY STAR
and press the Enter key.
If response indicates
no CBsy STARs
CBsy STARs
To post the STAR with the alarm condition, type
>POST STAR CBSY
and press the Enter key.
To identify C-side links to the host PM, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0 2; Cap MS; Status: SysB ;MsgCond: CLS
Link 1: LTC 0 6; Cap MS; Status: SysB ;MsgCond: CLS
To post the host PM, type
>POST pm_type pm_no
and press the Enter key.
where
Do
step 11
step 4