star_unit
is the STAR unit to be tested (0 or 1)
If test
passes
fails because of a loading error
fails, and generates a card list
fails, but does not generate a
card list
19
To try to load the STAR unit, type
>LOADPM UNIT star_unit CC
and press the Enter key.
where
star_unit
is the STAR unit to be loaded (0 or 1)
If load is
successful
not successful
20
To try to return the STAR unit to service, type
>RTS UNIT star_unit
and press the Enter key.
where
star_unit
is the STAR unit to be returned to service (0 or 1)
If RTS
passes
fails
21
Check the fuses on the FSP.
If fuses are
blown (indicator protruding)
not blown
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
major
Do
step 20
step 19
step 26
step 27
Do
step 20
step 27
Do
step 29
step 27
Do
step 22
step 18