Customer Replaceable Units

Top Cover Interlock Sensor and Actuator

Required Tools
2 mm hex wrench
2.5 mm hex wrench
Removing Top Cover Interlock Sensor
1. Power OFF the printer. See
2. Open the front top cover.
3. Disconnect the top cover sensor cable at the quick disconnect.
4. Remove the three cable ties that secure the cable to the sensor mounting bracket.
5. Use a 2 mm hex wrench to remove the sensor mounting screws (2). See
6. Remove the top cover sensor from the mounting bracket.
7. Use a 2.5 mm hex wrench to remove the top cover actuator mounting screws (2). See
Figure 57 (page
"Powering Off" (page
Figure 56: Top Cover Sensor Mounting Screw Locations
213).
© Copyright 2021 Stratasys. All rights reserved.
Top Cover Interlock Sensor and Actuator
181).
Figure
56.