Tip Calibration
If the Delta X and the Delta Y values are both within the range of -0.002 to
+0.002 in., the printer is calibrated and an adjustment is not required. The following
figure shows an XY offset within tolerance, requiring no adjustments. Proceed to
step
3.
Figure 13: XY Offset - No Adjustment Required
Sliding scale
icons (4)
If either of the Delta X or Delta Y values are outside the range of -0.002 to
+0.002 in., the printer requires an adjustment. The following figure shows the Delta
X value of 0.0050 in. and the Delta Y value of -0.0030 in. are both outside of the
acceptable range.
Figure 14: XY Offset - Adjustment Required