Tip Calibration
d. If an adjustment is required, you will need to rebuild the calibration part. To do so:
e. Proceed to the Z offset adjustment
3. Determine the Z Offset Adjustment.
a. Peel the support layer from the inner square of the calibration part.
b. Measure the thickness of the support layer on each side of the square with a caliper or
After entering your adjustment value(s) press the Apply button within the Manual
Tip Calibration page (see
adjustment(s) will be saved. If you continue to change the adjustment values, you
must press the Apply button again to save the changes.
The Cancel button can be used to reset an adjustment value entered prior to
pressing the Apply button. Once the Apply button is pressed, values will be
saved and the printer's calibration settings will reflect the adjustment value
entered. Use caution when entering an adjustment value to ensure it is correct
prior to pressing the Apply button.
After pressing the Apply button, the Close button will appear. Press the Close
button to return to the initial Tip Calibration page.
Repeat
step 1
above to build a calibration part.
Repeat the instructions in
Readjust until both of the Delta X and Delta Y values are within tolerance, which is
within -0.002 to +0.002 in.
X and Y is within tolerance.
The Z Offset Adjustment is not needed when using TPU 92A material.
micrometer. Measure in the center of each side; measuring near the corners will result
in inaccurate values.
© Copyright 2021 Stratasys. All rights reserved.
Figure 9 (page 153)
Figure 15: Close Button Location
step
2. Continue to check and adjust for XY offset.
(step 3
below) once the calibration toolpath for
Manual Tip Calibration
for button location). Your calibration
Page 157