Bit
Signal name
6
c_out_comm
7
d_out_comm
8
skewpos_ext
9
ska_in_comm
10
ska_out_comm
11
move_ska
12
reset_mdl
13
hold_trim_list
14-15
-
4.1.6

Targets

Table 4-12
SIMATIC S7 → SIMOTION D4x5-2 DP/PN, Targets
PZD
Signal name
1
STW1_PLC_Targets
2
LANE_SHIP_LOAD
LANE_SHIP_UNLOAD
3
LEARN_POS_LANE
4-6
-
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Remark
0: No command
1: Control cylinder C with positive velocity
0: No command
1: Control cylinder D with positive velocity
0: No command
1: Set position for the electric skew drive is specified from an external source.
0: No command
1: Travel of the skew axis (negative velocity) via the internal setpoint generator
0: No command
1: Travel of the skew axis (positive velocity) via the internal setpoint generator
0: No command
Activation of the move command via the skew axis position control
0: No command
1: Resetting an internal oscillation model
0: No command
1: Hold the trim and list positions
Reserved
Unit
Format
Remark
-
WORD
Control word
(see below, Table STW1_PLC_Targets)
1...99
SINT
Load lane number
This lane is used during loading.
1...99
SINT
Unload lane number
This lane is used during unloading.
-
SINT
Save position
Save the current lane position.
Reserved
Communication interface to SIMATIC S7
4.1 SIMATIC S7 → SIMOTION D for AddOn